CNCezPRO™ Software

Real-Time 3D Graphics Simulation for Computer Numerical Control



G99 FEEDRATE PER REVOLUTION
N_ G99
The G99 command sets the feedrate to units (inch or millimeter) per revolution. The setting depends on which type of unit is currently active.
Example G99
% (PROGRAM START FLAG)
:1099
N5 G20 G40 G99
N10 T1212 M08
N15 G98 M03 S2000
N20 G00 X0
N25 Z0.1
N30 G01 Z-0.2 F2
N35 G00 Z3
N40 X4 T1200
N45 T1010
N50 G00 X0
N55 Z0.1
N60 G74 Z-1 F0.5 D0 K0.25
N65 G99 G00 Z3
N70 T1000 X4
N75 T0101
N80 G00 X0.75
N85 Z0.1
N90 G01 Z0 F0.015
N95 X1.5
N100 G03 X2 Z-0.25 I0 K-0.25
N105 G01 X1.75 Z-1.5
N110 X2 Z-3
N115 G00 X4 Z3 M09
120 T0100 M05
N125 M02